Condé Gas Engine Vacuum Units are designed to use with vacuum tank systems. These units are ideal for truck systems that require auxiliary power. Gas units are complete and require only a line from the vacuum pump to the tank for installation. If you have a tank, we have a complete vacuum unit ready for easy and quick installation to get your system up and running fast. All gasoline powered units are complete with relief valves and supplied with oil catch muffler. As with all vacuum systems, a primary shut-off and secondary moisture trap should be installed in the line from the pump to the tank. 


Condé SDS Ultra Unit

Condé Model SDS Ultra
SDS Ultra Tank System Accessories

Download Specifications

PDF documents: best viewed with Adobe Acrobat 4.0 or higher. Click icon below for free download.

 

Maximum air flow
SCFM at 15" Hg
Engine
Weight
Oiler
Drive System
- 230 cubic feet per minute @ free air
- 115
- Briggs Vanguard Twin, electric start
- 350 lbs.
- Automatic
- V Belt with guards

Vacuum only or Vacuum/Pressure
Recommended Tank Size- 1200 to 2500 gallons

 

Pull Down Time to 15" Hg
- 1000 gallons
- 1500 gallons
- 2000 gallons
- 2500 gallons
- 25 seconds
- 39 seconds
- 52 seconds
- 65 seconds


 


 

Condé SDS 12 Unit

Condé Model 12 SDS
12 SDS Tank System Accessories

Download Specifications

 

Maximum air flow
SCFM at 15" Hg
Engine
Weight
Oiler
Drive System
- 180 cubic feet per minute @ free air
- 90
- Honda GX390, electric start
- 275 lbs.
- Automatic
- V Belt with guards

Vacuum only or Vacuum/Pressure
Recommended Tank Size- 1000 to 2000 gallons

 

Pull Down Time to 15" Hg
- 500 gallons
- 750 gallons
- 1000 gallons
- 1500 gallons
- 2000 gallons
- 16 seconds
- 24 seconds
- 32 seconds
- 50 seconds
- 67 seconds

 



 

Condé SDS 6 Unit

Condé SDS 6 HD
SDS 6 Tank System Accessories

Download Specifications

 

Maximum air flow
SCFM at 15" Hg
Engine
Weight
Oiler
Drive System
- 115 cubic feet per minute @ free air
- 58
- Honda GX270, electric start
- 200 lbs.
- Automatic
- V Belt with guards

Vacuum only or Vacuum/Pressure
Recommended Tank Size- 500 to 1000 gallons

 

Pull Down Time
to 15" Hg

- 500 gallons
- 750 gallons
- 1000 gallons
- 1500 gallons
- 2000 gallons

- 26 seconds
- 40 seconds
- 53 seconds
- 80 seconds
- 106 seconds

 




Condé SDS 6 Direct Drive Unit

Pump is not engaged at idle allowing for longer pump life

Condé SDS6,9 hp Direct Drive Unit
SDS 6, 9 hp Direct Drive Accessories

Download Specifications

 

Maximum air flow
SCFM at 15" Hg
Engine
Weight
Oiler
Drive System
- 115 cubic feet per minute @ free air
- 58
- Honda GX270, electric start
- 200 lbs.
- Automatic
- Direct Drive, 2:1 ratio with centrifugal clutch

Vacuum only or Vacuum/Pressure
Recommended Tank Size- 500 to 1000 gallons

 

Pull Down Time
to 15" Hg

- 500 gallons
- 750 gallons
- 1000 gallons
- 1500 gallons
- 2000 gallons

- 26 seconds
- 40 seconds
- 53 seconds
- 80 seconds
- 106 seconds

 




Condé Model Super 6 HP Unit

Condé Super 6 HD
Super 6 Tank System Accessories

Download Specifications

Maximum air flow
SCFM at 15" Hg
Engine
Weight
Oiler
Drive System
- 70 cubic feet per minute @ free air
- 35
- Honda GX160, electric start
- 175 lbs.
- Automatic
- V Belt with guards

Vacuum only and Vacuum/Pressure
Recommended Tank Size- 300 to 500 gallons

 

Pull Down Time
to 15" Hg

- 100 gallons
- 200 gallons
- 300 gallons
- 400 gallons
- 500 gallons

- 8 seconds
- 17 seconds
- 25 seconds
- 34 seconds
- 52 seconds

 


super 6 direct drive 3

Condé Model Super 6 Unit Direct Drive
Pump is not engaged when motor is at idle, allowing for longer pump lifeDownload Specifications
 

 

super 6 direct drive 4

Maximum air flow
SCFM at 15" Hg
Engine
Weight
Oiler
Drive System
- 70 cubic feet per minute @ free air
- 35
- Honda GX160, electric start
- 175 lbs.
- Automatic
- Direct Drive, 2:1 ratio with centrifugal clutch

Vacuum only and Vacuum/Pressure
Recommended Tank Size- 300 to 500 gallons

Pull Down Time
to 15" Hg

- 100 gallons
- 200 gallons
- 300 gallons
- 400 gallons
- 500 gallons

- 8 seconds
- 17 seconds
- 25 seconds
- 34 seconds
- 52 seconds

Condé ProVac 3

Condé ProVac 3 HD
ProVac 3 Tank System Accessories

Download Specifications

 

Maximum air flow
SCFM at 15" Hg
Engine
Weight
Oiler
Drive System
- 35 cubic feet per minute @ free air
- 18
- Honda GX100 pull start or GX160 electric start
- 1600 lbs.
- Automatic
- V Belt with guards

Vacuum only or Remote Slide Valve for Vacuum/Pressure
Recommended Tank Size- 100 to 300 gallons

 

Pull Down Time
to 15" Hg

- 100 gallons
- 250 gallons
- 300 gallons
- 400 gallons
- 500 gallons

- 16 seconds
- 37 seconds
- 50 seconds
- 64 seconds
- 84 seconds

 Condé ProVac 3, Direct Drive

Pump is not engaged at idle allowing for longer pump life

Provac 3 direct drive


Download Specifications

Maximum air flow
SCFM at 15" Hg
Engine
Weight
Oiler
Drive System
- 35 cubic feet per minute @ free air
- 18
- Honda GX160 electric start
- 1600 lbs.
- Automatic
- Direct Drive, 2:1 ratio with centrifugal clutch

Vacuum only or Remote Slide Valve for Vacuum/Pressure
Recommended Tank Size- 100 to 300 gallons

Pull Down Time
to 15" Hg

- 100 gallons
- 250 gallons
- 300 gallons
- 400 gallons
- 500 gallons

- 16 seconds
- 37 seconds
- 50 seconds
- 64 seconds
- 84 seconds
Part No. Description  
OLUNSDSULT18
SDS Ultra, Vac. Only, Twin Vanguard Briggs El. Start

 


HDUNSDSULT18
SDS Ultra, Vac/Press., Twin Vanguard Briggs El. Start

 


OLUN12SDS13E
SDS 12, Vac. Only, GX390 Honda El. Start

 

 
HDUN12SDS13E
SDS 12, Vac/Pres., GX390 Honda El. Start

 

 
OLUN06SDS09E
SDS 6, Vac. Only, GX270 Honda El. start

 


HDUN06SDS09E
SDS 6, Vac/Press, GX270 Honda El. start

 


OLUN06SDS9DD
SDS 6,9 hp Direct Drive Unit  GX270 Honda El. start

 


HDUN06SDS9DD
SDS 6,9 hp Direct Drive Unit GX270 Honda El. start

 


OLUN06SS05ES
Super 6, Vac. Only, GX160 Honda El. Start

 

 
HDUN06SS05ES
Super 6, Vac/Pres.,GX160 Honda El. Start

 


OLUN03PV05ES
ProVac 3, Vac. Only, GX160 Honda, El. Start

 

 
OLUN03PV3PS
ProVac 3, Vac only, GX100 Honda, Pull Start

 


HDUN03PV05ES
ProVac 3, Vac/Pres.,GX160 Honda El. Start
Download specifications:
SUPER 6/12 Manual
SDS Manual